Model |
30Kw |
40Kw |
50Kw |
60Kw |
75Kw |
80Kw |
Battery Input Data |
Battery Type |
Lithium-ion |
Battery Voltage Range (V) |
160-800 |
160-1000 |
Max. Charge/Discharge Current (A) |
50+50 |
80+80 |
Charging Strategy for Li-ion Battery |
Self-adaption to BMS |
Number of Battery Input |
2 |
PV String Input Data |
Max. PV Access Power (W) |
60000 |
80000 |
100000 |
120000 |
150000 |
160000 |
Max. PV Input Power (W) |
48000 |
64000 |
80000 |
96000 |
120000 |
128000 |
MPPT Voltage Range (V) |
150-850 |
Rated PV Input Voltage (V) |
600 |
650 |
Max. Operating PV Input Current (A) |
36+36+36 |
36+36+36+36 |
36+36+36+36+36+36 |
Max. Input Short-Circuit Current (A) |
55+55+55 |
55+55+55+55 |
54+54+54+54+54+54 |
No. of MPP Trackers/No. of Strings MPP Tracker |
3/2+2+2 |
4/2+2+2+2 |
6/2+2+2+2+2+2 |
AC Input/Output Data |
Rated AC Input/Output Active Power (W) |
30000 |
40000 |
50000 |
60000 |
75000 |
80000 |
Max. AC Input/Output Apparent Power (VA) |
33000 |
44000 |
55000 |
66000 |
82500 |
88000 |
Rated AC Input/Output Current (A) |
45.5/43.5 |
60.7/58 |
75.8/72.5 |
91/87 |
113.7/108.7 |
121.3/115.9 |
Max. AC Input/Output Current (A) |
50/47.9 |
66.7/63.8 |
83.4/79.8 |
100/95.7 |
125/119.6 |
133.4/127.6 |
Max. Continuous AC Passthrough (grid to load) (A) |
100 |
200 |
Peak Power (off-grid) (W) |
1.5 times of rated power, 10s |
Power Factor Adjustment Range |
0.8 leading to 0.8 lagging |
Rated Input/Output Voltage/Range (V) |
220/380V, 230/400V 0.85Un-1.1Un |
Rated Input/Output Grid Frequency/Range(Hz) |
50/45-55, 60/55-65 |
Grid Connection Form |
3L+N+PE |
DC Injection Current |
<0.5% In |
Total Current Harmonic Distortion THDi |
<3% (of nominal power) |
Efficiency |
Max. Efficiency |
97.60% |
97.60% |
Euro Efficiency |
97.00% |
97.00% |
MPPT Efficiency |
>99% |
Interface |
Communication Interface |
CAN, RS485, Ethernet, Optional: Wi-Fi, Cellular, LAN |
RS485/RS232/CAN |
Monitor Mode |
GPRS/WIFI/Bluetooth/4G/LAN(optional) |
General Data |
Operating Temperature Range (ºC) |
-40 to +60ºC, >45ºC Derating |
Permissible Ambient Humidity |
0-100% |
Permissible Altitude |
2000m |
3000m |
Noise (dB) |
≤65 |
Ingress Protection(IP) Rating |
IP 65 |
Inverter Topology |
Non-Isolated |
Over Voltage Category |
OVC II(DC), OVC III(AC) |
Cabinet Size (WxHxD mm) |
527*894*294(Excluding connectors and brackets) |
606×927×314 (Excluding Connectors and Brackets) |
Weight (kg) |
80 |
97.5 |
Type of Cooling |
Intelligent Air Cooling |
Warranty |
5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy |